Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol
Parameter
Min
Max
Unit
V
CC
Operating Voltage
Operating 1.65
5.5
V
Data retention only
1.5
—
V
V
IH
High-Level Input Voltage
V
CC
= 1.65V to 1.95V
0.65 X V
CC
—
V
V
CC
= 2.3V to 2.7V
1.7 —
V
CC
= 3V to 3.6V
2 —
V
CC
= 4.5V to 5.5V
0.7 X V
CC
—
V
IL
Low-Level Input Voltage
V
CC
= 1.65V to 1.95V
—
0.35 X V
CC
V
V
CC
= 2.3V to 2.7V
— 0.7
V
CC
= 3V to 3.6V
— 0.8
V
CC
= 4.5V to 5.5V
—
0.3 X V
CC
V
I
Input Voltage
0 5.5 V
V
O
Output Voltage
0
V
CC
V
I
OH
High-Level Output Current
V
CC
= 1.65V
— -4
mA
V
CC
= 2.3V
— -8
V
CC
= 3V
— -16
— -24
V
CC
= 4.5V
— -32
I
OL
Low-Level Output Current
V
CC
= 1.65V
— 4
mA
V
CC
= 2.3V
— 8
V
CC
= 3V
— 16
— 24
V
CC
= 4.5V
— 32
∆t/∆V
Input transition rise or fall rate
V
CC
= 1.8V ± 0.15V, 2.5V ± 0.2V
— 20
ns/V
V
CC
= 3.3V ± 0.3V
— 10
V
CC
= 5V ± 0.5V
— 5
T
A
Operating free-air temperature
—
-40
+125
°C
Note: 5. Unused inputs should be held at V
CC