Processor supervisory circuits, Electrical characteristics – Diodes APX823/APX824/APX825A User Manual
Page 4
APX823/APX824/APX825A
PROCESSOR SUPERVISORY CIRCUITS
APX823/APX824/APX825A
Document number: DS31323 Rev. 4 - 2
4 of 12
May 2011
© Diodes Incorporated
Electrical Characteristics
(Over recommended operating ambient temperature range, unless otherwise noted)
Symbol
Parameter
Test Conditions
Min
Typ.
Max
Unit
V
OH
High-level
Output Voltage
RESET
APX823/APX824/APX825A -
29/26/23
V
CC
= V
TH-
+0.2V
I
OH
=-20
μA
0.8
×
V
CC
- - V
APX823/APX824/APX825A -
40/31
V
CC
= V
TH-
+0.2V
I
OH
=-30
μA
APX823/APX824/APX825A
–46/44
V
CC
= V
TH-
+0.2V
I
OH
=-120
μA
V
CC
-1.5V
- - V
RESET
APX824/APX825A
-29/26/23
V
CC
> 1.8V,
I
OH
= -100
μA
0.8
×
V
CC
- - V
APX824/APX825A -
46/44/40/31
V
CC
> 1.8V,
I
OH
= -150
μA
V
OL
Low-level
Output Voltage
RESET
APX824/APX825A
-29/26/23
V
CC
= V
TH-
+0.2V
I
OL
=1mA
- -
0.4
V
APX824/APX825A -40/31
V
CC
= V
TH-
+0.2V
I
OL
=1.2mA
APX824/APX825A -46/44
V
CC
= V
TH-
+0.2V
I
OL
=3mA
RESET
APX823/APX824/APX825A -
29/26/23
V
CC
= V
TH-
-0.2V
I
OL
=1mA
- -
0.4
V
APX823/APX824/APX825A -
40/31
V
CC
= V
TH-
-0.2V
I
OL
=1.2mA
APX823/APX824/APX825A -
46/44
V
CC
= V
TH-
-0.2V
I
OL
=3mA
V
RESET
Power-up Reset Voltage (see Note 2)
V
CC
> 1.1V,
I
OL
=20
μA
- -
0.4
V
V
TH-
Negative-going
Input Threshold
Voltage
(see Note 3)
APX823/APX824/APX825A -23
T
A
= 0
o
C -85
o
C
2.21 2.25 2.30
V
APX823/APX824/APX825A -26
2.59
2.63
2.69
APX823/APX824/APX825A -29
2.88
2.93
3.00
APX823/APX824/APX825A -31
3.02
3.08
3.15
APX823/APX824/APX825A -40
3.93
4.00
4.08
APX823/APX824/APX825A -44
4.31
4.38
4.47
APX823/APX824/APX825A -46
4.56
4.63
4.72
APX823/APX824/APX825A -23
T
A
= -40
o
C -85
o
C
2.20 2.25 2.30
V
APX823/APX824/APX825A -26
2.57
2.63
2.69
APX823/APX824/APX825A -29
2.86
2.93
3.00
APX823/APX824/APX825A -31
3.00
3.08
3.15
APX823/APX824/APX825A -40
3.92
4.00
4.08
APX823/APX824/APX825A -44
4.29
4.38
4.47
APX823/APX824/APX825A -46
4.54
4.63
4.72
Note:
2. The lowest supply voltage at which RESET becomes active. T
R
, V
CC
> 15
μs/V.
3. To ensure best stability of the threshold voltage, a bypass capacitor (ceramic, 0.1
μF) should be placed near the supply terminals.