Absolute Maximum Ratings

(Over operating ambient temperature range, unless otherwise noted)*

Symbol

Parameter

Rating

Unit

ESD HBM Human Body Model ESD Protection

5

KV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage

6.0

V

V

RESET

RESET,

RESET

,

MR

, WDI

-0.3 to (V

CC

+0.3)

V

I

CC

Input Current V

CC

20 mA

I

O

Maximum High Output Current

20

mA

P

D

Continuous Total Power
Dissipation

Derating Factor Above

T

A

= 25

o

C

SOT25 6.2

mW/°C

SOT26 5.8

T

A

= 25

o

C Power Rating

SOT25 500

mW

SOT26 470

T

A

= 70

o

C Power Rating

SOT25 220

mW

SOT26 210

T

A

= 85

o

C Power Rating

SOT25 125

mW

SOT26 120

T

OP

Operating Junction Temperature Range

-40 to 105

°C

T

ST

Storage Temperature Range

-65 to 150

°C

* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional

operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.

Recommended Operating Conditions

Symbol

Parameter

Min

Max

Unit

V

CC

Supply Voltage

1.1

5.5

V

V

IN

Input Voltage

0

(V

CC

+0.3)

V

V

IH

High-level Input Voltage at

MR

and WDI

0.7

×

V

CC

- V

V

IL

Low-level Voltage

-

0.3

×

V

CC

V

Δt/ΔV

Input Transition Rise and Fall Rate at

MR

or WDI

- 100

ns/V

T

A

Operating Ambient Temperature Range

-40

85

o

C

T

R

V

CC

Rising Time (V

CC

= 0~VT)

- 100

V/

uS