APX823/APX824/APX825A
PROCESSOR SUPERVISORY CIRCUITS
APX823/APX824/APX825A
Document number: DS31323 Rev. 4 - 2
3 of 12
May 2011
© Diodes Incorporated
Absolute Maximum Ratings
(Over operating ambient temperature range, unless otherwise noted)*
Symbol
Parameter
Rating
Unit
ESD HBM Human Body Model ESD Protection
5
KV
ESD MM
Machine Model ESD Protection
200
V
V
CC
Supply Voltage
6.0
V
V
RESET
RESET,
RESET
,
MR
, WDI
-0.3 to (V
CC
+0.3)
V
I
CC
Input Current V
CC
20 mA
I
O
Maximum High Output Current
20
mA
P
D
Continuous Total Power
Dissipation
Derating Factor Above
T
A
= 25
o
C
SOT25 6.2
mW/°C
SOT26 5.8
T
A
= 25
o
C Power Rating
SOT25 500
mW
SOT26 470
T
A
= 70
o
C Power Rating
SOT25 220
mW
SOT26 210
T
A
= 85
o
C Power Rating
SOT25 125
mW
SOT26 120
T
OP
Operating Junction Temperature Range
-40 to 105
°C
T
ST
Storage Temperature Range
-65 to 150
°C
* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
Recommended Operating Conditions
Symbol
Parameter
Min
Max
Unit
V
CC
Supply Voltage
1.1
5.5
V
V
IN
Input Voltage
0
(V
CC
+0.3)
V
V
IH
High-level Input Voltage at
MR
and WDI
0.7
×
V
CC
- V
V
IL
Low-level Voltage
-
0.3
×
V
CC
V
Δt/ΔV
Input Transition Rise and Fall Rate at
MR
or WDI
- 100
ns/V
T
A
Operating Ambient Temperature Range
-40
85
o
C
T
R
V
CC
Rising Time (V
CC
= 0~VT)
- 100
V/
uS