Ah266, Recommended operating conditions, Electrical characteristics – Diodes AH266 User Manual
Page 3: Test circuit, 24v v, 1 (do) v, 2 (dob)

AH266
Document number: DS30876 Rev. 5 - 2
3 of 7
December 2013
© Diodes Incorporated
AH266
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol Characteristic Conditions
Min
Max
Unit
V
CC
Supply Voltage
Operating
4
28
V
T
A
Operating Ambient Temperature (Note 7)
Operating
-20
85
°C
Notes:
4. This application circuit can’t protect reverse coil current if power is connecting reverse.
5. I
o (con)
is 150 mA at +85°C.
6. See Performance Characteristics for other conditions.
7. Shall not exceed P
D
and Safety Operation Area.
Electrical Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Symbol Characteristic
Conditions
Min
Typ.
Max
Unit
V
z
Output Zener Breakdown
Output Turn off
54
62
70
V
V
CE (SAT)
Output Saturation Voltage
V
CC
= 24V, I
C
= 400mA
-
1.1 1.5 V
I
CEX
Output Leakage Current
V
CE
= 24V, V
CC
= 24V
-
<
0.1
10
μA
I
CC
Supply Current
V
CC
= 24V, Output Open
-
5
10
mA
tr
Output Rise Time
V
CC
= 24V, RL = 820Ω, CL = 20pF
-
1.0 5
µs
tf Output
Falling
Time
V
CC
= 24V, RL = 820Ω, CL = 20pF
-
1.0 1.5
µs
t
Switch Time Differential
V
CC
= 24V, RL = 820Ω, CL = 20pF
-
3.0 10
µs
Test Circuit
266
CL1
CL2
24V
V
out
1 (DO)
V
out
2 (DOB)
RL1 = RL2 = 820 Ohm
CL1 = CL2 = 20 pF
RL2
RL1