beautypg.com

AVSL Citronic CLA-300 User Manual

Page 4

background image

171.227, 171.228 User Manual

Assembly

The CLA-300 may be assembled as a single vertically flown array, inverted as a floor-standing stack

or combined into a multiple array. Assembly for standard flown orientation is shown below.

1. Secure the 4 x M8 eyebolts to the corners of the flying frame. Each eyebolt must be securely

fixed using the appropriate hardware to ensure that there is no movement of the fixing or

possibility of becoming unfastened through movement or vibration and should be suspended
from a permanent fixing in the ceiling which is adequate for holding the weight of the complete
line-array.

2. Undo the M5 thumb screws at the bottom of the active sub and take out the Passive-Active Link
3. Undo the 2 x M5 thumb screws at front side of the passive unit, align the holes with similar at

the base of the sub and fasten the M5 screws through both, securing passive units to the sub

4. Attach the Passive-Active Link and Passive Back Link brackets as shown below (Angle adjustment

is explained in the “Installation” section)