Bios setup, 1 chip configuration – Asus CUV266 User Manual

Page 64

background image

ASUS CUV266 User’s Manual

64

4. BIOS SETUP

4. BIOS SETUP

Chip Configuration

SDRAM Configuration [By SPD]

This sets the optimal timings for items 2–5, depending on the memory
modules that you are using. The default setting is [By SPD], which configures
items 2–5 by reading the contents in the SPD (Serial Presence Detect) device.
The EEPROM on the memory module stores critical parameter information
about the module, such as memory type, size, speed, voltage interface, and
module banks. Configuration options: [User Defined] [7ns (143MHz)] [8ns
(125MHz)] [By SPD]

SDRAM CAS Latency [3T]

This controls the latency between the SDRAM read command and the
time that the data actually becomes available. NOTE: This field appears
only when you set the SDRAM Configuration to [User Defined].

SDRAM RAS Precharge Time [3T]

This controls the idle clocks after issuing a precharge command to the
SDRAM. NOTE: This field appears only when you set the SDRAM
Configuration
to [User Defined].

4.4.1 Chip Configuration

(Scroll down to see more items as shown)