MIL-PRF-55310/38B

5

Frequency aging: Measurements shall be taken at +70

°C ±0.2°C at intervals of not more than every 72 hours for

30 days minimum (Except one maximum interval of 96 hours per 30 days is permitted).


±10 ppm per year, maximum

±1.5 ppm per 30 days.

±3 ppm per 90 days.


Terminal strength:

Method 211 of MIL-STD-202

, test condition A.


Applied force: 8 ounces each terminal.

Frequency-environmental tolerance: Not applicable.

Vibration, sinusoidal: In accordance with

MIL-PRF-55310

and

method 204 of MIL-STD-202

.


Nonoperating: Test condition G.

Operating: Not required.

Ambient pressure:

Nonoperating: In accordance with

MIL-PRF-55310

.


Operating:

Method 105 of MIL-STD-202

, test condition C.


Exposure time: 5 minutes.

Reflow soldering: Reflow soldering of the unit at +230

°C ±10°C for 15 seconds shall not degrade the performance.


Part or Identifying Number (PIN): Consists of “M” prefix followed by specification sheet number, a dash and coded
alphas, and numeric number. See example:

EXAMPLE

M55310/38-

S

01

A

XXXXXXXX


M prefix and specification sheet number

Product level (S, B, or C)

Dash number (see

table I

)

Operating temperature range
(A, B, or C) (see

table I

)

Frequency


Referenced documents. In addition to

MIL-PRF-55310

, this document references

MIL-STD-202

.