MIL-PRF-55310/8J
4
TABLE I. Dash numbers and operating characteristics.
Frequency-voltage tolerance:
2 ppm maximum for a 10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
Frequency aging: Measurements shall be taken at +70
C 0.2C at intervals of not more than every 72 hours for
30 days minimum.
5 Hz to 4.9 MHz
5MHz to 50 MHz
1 ppm per 30 days, maximum.
2 ppm per 30 days, maximum
2 ppm per 90 days, maximum. 2/
4 ppm per 90 days, maximum
5 ppm per year, maximum. 2/
10 ppm per year, maximum
Te
Applied force: 2 pounds each terminal for 10 seconds.
Bends: Five at 45 degrees each.
Frequency-environmental tolerance: Not applicable.
2/ This is a performance requirement of the oscillator. Support data shall be presented showing that this
requirement shall be met.
Dash
number
Output
frequency
range
Supply
voltage
Input
current
(max)
Output voltage
Rise
and
fall
times
(max)
Duty
cycle
at 1.4 V
Frequency-temperature
tolerance (ppm)
Logic: 1
(min)
Logic: 0
(max)
-55
C
to
+125
C
-55
C
to
+105
C
-20
C
to
+70
C
A B C
V
dc mA
ns percent
01
1 kHz to
150 kHz
+5
0.25
158
15
45 to 55
50
40
25
02
150 kHz to
300 kHz
+5
0.25
94
15
45 to 55
50
40
25
03
300 kHz to
600 kHz
+5
0.25
94
15
45 to 55
50
40
25
04
600 kHz to
2.5 MHz
+5
0.25
50
2.4 V dc
at 400
A
0.5 V dc
at 16 mA
15
45 to 55
50
40
25
05
2.5 MHz to
5 MHz
+5
0.25
50
source
sink
15
45 to 55
50
40
25
06
5 MHz to
10 MHz
+5
0.25
35
15
40 to 60
50
40
25
07
10 MHz to
20 MHz
+5
0.25
25
15
40 to 60
50
40
25
08
20 MHz to
30 MHz
+5
0.25
35
5
40 to 60
50
40
25
09
30 MHz to
50 MHz
+5
0.25
50
5
40 to 60
50
40
25
10
50 Hz to
1 kHz
+5
0.25
158
15
40 to 60
50
40
25