Q-Tech QT6C User Manual
Page 5

MIL-PRF-55310/18F
5
Frequency-voltage tolerance:
2 ppm maximum for a 10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
Frequency aging: Measurements shall be taken at +70
C 0.2C at intervals of not more than every 72 hours for
30 days minimum (see table I).
5 ppm per year, maximum
10 ppm per year, maximum
0.7 ppm per 30 days.
1.5 ppm per 30 days
1.5 ppm per 90 days
3 ppm per 90 days
Te
, test condition C.
Applied force: 2 pounds each terminal for 10 seconds.
Bends: Five at 45 degrees each.
Frequency-environmental tolerance: Not applicable.
Vibration, sinusoidal: In accordance wi
Nonoperating: Test condition D.
Operating: Not required.
Ambient pressure:
Nonoperating: In accordance wi
Part or Identifying Number (PIN): Consists of “M” prefix followed by specification sheet number, a dash and coded
alphas, and numeric number. See example:
EXAMPLE
M55310/18- S 01
A XXXXXXXX
M prefix and specification sheet number
Product level (S, B, or C)
Dash number (see table I)
Operating temperature range
(A, B, or C) (see table I)
Frequency