MIL-PRF-55310/18F

5

Frequency-voltage tolerance:

2 ppm maximum for a 10 percent change in supply voltage. Measurements taken

at reference temperature and operating temperature range end points.

Frequency aging: Measurements shall be taken at +70

C 0.2C at intervals of not more than every 72 hours for

30 days minimum (see table I).

5 ppm per year, maximum

10 ppm per year, maximum


0.7 ppm per 30 days.

1.5 ppm per 30 days

1.5 ppm per 90 days

3 ppm per 90 days


Terminal strength:

Method 211 of MIL-STD-202

, test condition C.


Applied force: 2 pounds each terminal for 10 seconds.

Bends: Five at 45 degrees each.

Frequency-environmental tolerance: Not applicable.

Vibration, sinusoidal: In accordance with

MIL-PRF-55310

and

method 204 of MIL-STD-202

.


Nonoperating: Test condition D.

Operating: Not required.

Ambient pressure:

Nonoperating: In accordance with

MIL-PRF-55310

.


Operating:

Method 105 of MIL-STD-202

, test condition C.


Part or Identifying Number (PIN): Consists of “M” prefix followed by specification sheet number, a dash and coded
alphas, and numeric number. See example:

EXAMPLE

M55310/18- S 01

A XXXXXXXX


M prefix and specification sheet number

Product level (S, B, or C)

Dash number (see table I)

Operating temperature range
(A, B, or C) (see table I)

Frequency