Calibration controls – Universal Audio UAD Plug-Ins ver.7.4.2 User Manual
Page 463

UAD Powered Plug-Ins Manual
- 463 -
Chapter 47: Studer A800
• Gang Controls is a static control without the ability to make relative offsets.
Disable Gang Controls if offsets between the same control within different
instantiations is desired.
• If Gang Controls is enabled when Auto Cal is enabled, any adjustments
made to Tape Type, Tape Speed or Emphasis EQ causes the
to be automatically adjusted for all instantiations. However, if the
Tape Type, Tape Speed or Emphasis EQ values do not already match be-
tween instantiations before Gang Controls is active, the resulting calibrated
values may not match either.
• When Gang Controls is enabled, there are no audible or visual changes to
the other Studer A800 instantiations until a control is actually changed.
• When Gang Controls is enabled and a Studer A800 settings preset is
loaded via the UAD Toolbar, the loaded parameter settings are pushed to
all Studer A800 instances.
Calibration
Controls
for the HF Record EQ, Bias, Sync EQ, and
Repro EQ controls. These controls are automatically adjusted when
is active, or they can be manually modified as desired.
The “flat” calibrated position for these controls is determined by Tape Type
and Tape Speed; therefore the available ± range for these controls is depen-
dent on the current calibration.
Tip:
Clicking the text label for any of the HF Record EQ, Bias, and Sync/Re-
pro EQ controls will return that parameter to the calibrated value.
Note:
When making manual calibration settings, consider disabling Auto
Cal (
) so the manually calibrated settings are not accidentally lost if
another control is modified.