Connections, Monitoring (sniffing) – SENA Parani-MSP1000 User Manual
Page 44

44
5.7. Connections
The SPP connections currently connected to the Parani-MSP1000 are displayed. Definitions and
descriptions of each parameter are described as follows:
Inf
The Bluetooth interface
BD address
The remote BD address
Service description
The network service linked with the SPP connection is displayed.
Figure 5-15 SPP connections
5.8. Monitoring (Sniffing)
The Parani-MSP1000 supports port monitoring (sniffing) functionality for debugging and installation.
The port monitoring enables the user to sniff the data received/sent from/to SPP.
To access the port monitoring:
1) Access the console management via Telnet or SSH
2) Select the Monitoring menu, SPP connections and the connection to sniff
-------------------------------------------------------------------------------
Welcome to MSP1000 configuration page
Current Time
: 8/26/2007 06:55:14
Serial No.
: MSP1000-00001
F/W Rev.
: v1.0.0
MAC Addr.(eth0) : 00:01:95:AF:BE:11
IP Mode (eth0) : Static
IP Addr.(eth0)
: 192.168.11.30
-------------------------------------------------------------------------------
1. Network configuration
2. System administration
3. System status & log
4. CF card configuration
5. Monitoring
6. Save changes
7. Exit without saving
8. Exit and apply changes
9. Exit and reboot
--> 5
--------------------------------------------------------------------------------