English, Maintenance & care – Pfister GT26-3NSS User Manual
Page 6
ENGLISH
ENGLISH
MAINTENANCE & CARE
24
21
22
23
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price
Pfister Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
21 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (21A). Turn Valve (21B) on and
allow both hot and cold water to run for at least one minute each. While water is running,
check for leaks. To clean the aerator, disassemble Aerator Housing (21A) by separating
the Aerator Shell (21C), Basket (21D), and Washer (21E). Once parts have been cleaned,
reassemble by reversing steps.
22 HANDLE REMOVAL
Carefully pry off Handle Cap (22A). Remove Retaining Screw (22B) and Handle Lever
(22C) from Valve Body (22D).
23 CARTRIDGE REMOVAL
Turn off water supplies and relieve pressure before working on your faucet.
Remove handle (see figure 22). Using pliers, unscrew the retainer ring (23A). Carefully
remove the Cartridge (23B) by pulling it straight up and out. Reassemble valve by
reversing steps.
24 HOSE REMOVAL
Turn off water supplies and relieve pressure.
To remove hose attachments from Diverter Tee (24F), push on Connection Fittings (24A
& 24B). Holding Plastic Collet (24C) in place, pull out on Connection Fittings (24A & 24B)
until Hoses (24D & 24E) are free.
6
21B
21A
21E
21D
21C
22B
22A
24A
24C
24F
24C
24B
24F
24D
24E
22C
23B
23A
22D