beautypg.com

General information, Outside trim, Maintenance – Factory Direct Hardware Von Duprin 22EOF4 User Manual

Page 2

background image

911333_00(9) Page 2 of 12

GENERAL INFORMATION

Review pages 2 and 3 so you can identify the hardware and understand the terminology used in the instructions.

See page 10 for the “Metric Conversion Table” if needed.

These exit devices can be installed on the door widths listed below:

Dogging panic device during high traffic periods

will increase life of device. To dog, depress pushbar

and turn hex key one-quarter turn clockwise.

NOTE

!

Standard 3’ (32”)

NFPA101

24-3/4” to 36”

Standard 4’ (44”)

NFPA101

30-3/4” to 48”

Device Size

Door Size

Code/Standard Requirement

TP-BE

(thumbpiece;

unlocked)

Escutcheon

(optional for

EO application)

DT

(pull when

dogged)

NL

(key retracts

latch bolt)

TP

(key locks

thumbpiece)

K

(key locks

knob)

L

(key locks

lever)

DT

(pull when

dogged)

NL

(key retracts

latch bolt)

OUTSIDE TRIM

No outside trim supplied for EO (exit only) application

Von Duprin 22 exit devices are designed and built to be maintenance free; however, such factors
as installation, severity of use, environmental conditions, and changes in the condition of the door
opening may require that maintenance and/or device adjustment be performed. The following
guidelines are recommended to the building owner to insure proper device operation:

1. Check device operation for smooth operation periodically.

2. Check strikes (keeper) and latches to insure they are secure.

3. Check latches and other moving parts for binding or sluggish operation due to dirt or chemical

buildup. Clean parts with soap and water and then lubricate with graphite-based or silicone
lubricants. Do not use petroleum-based lubricants.

MAINTENANCE