beautypg.com

Factory Direct Hardware Von Duprin 9947WDCEOF User Manual

Installation instructions, Wood door, Von duprin

background image

1

Measure amount to cut off device.

2” Minimum

clearance

(with end cap

removed)

5/16”

if 5/8” diameter wire

access hole has been

predrilled in door, mark

device to be cut 5/16”

from center of hole.

NOTE:

Device aligned with

mounting holes

2

CUT DEVICE

Cut device

square and

remove all

burrs

3

Cut device square.

Note: Device must

be cut square for

proper end cap fit

4

Tape

Cover plate

(flush to pushbar)

Pushbar

Tape and mark area being cut.

IMPORTANT: Dimension “C”

from pushbar to cut must be

no shorter than 10-3/4”

C

Remove

anti-rattle

clip

Slide anti-rattle clip into device.

Anti-rattle

clip

Installation Instructions

Devices covered by these instructions:

CX98/9947WDC Concealed Vertical Rod Device

CX98/9947WDC-F (Fire) Concealed Vertical Rod Device

This product is covered by the

following patent numbers:

3,767,238 4,427,223

3,854,763 4,466,643

4,167,280 4,741,563

CX98/9947WDC

Concealed Vertical Rod Device

Wood Door

Applications

911383_00(1) Copyright © 2002 Ingersoll-Rand. All rights reserved.

12

VON DUPRIN

®

Special tools needed:

5/64” hex wrench

#10-24 tap

Drill bits: #25, 1/8”, 1/4”,

5/16”, 13/32”

Index:

• Screw chart ................................................ 2
• Device installation ................................. 4-6
• Door routing instructions ........................ 7
• Door preparation chart ............................ 8
• Frame preparation chart .......................... 9
• Adjust rods ............................................... 10
• CD (cylinder dogging) ........................... 11
• Cut device ................................................ 12

911383-00

Controlled Exit Device

This manual is related to the following products: