4

Install the new cup washers and springs in the rough.

Install the cartridge assembly.

Installation with 38111181 rough manufactured after 04/2004

Remove the covers from the plaster shields.

Trim the plaster shields so that they extend 1/16”

outside the surface of the finished wall. Seal the wall

around the plaster shield with waterproof sealant.

Use a 17 mm socket wrench to remove the spout plug.

Use a 7 mm socket wrench to remove the cartridge

housing. Remove and discard the flush insert.

Turn the water off at the supply before

beginning this installation.

1.

2.