Power-Up Modes

The iEQ Series EQs provide the ability to lock the front panel controls and edit how AFS will function�
These changes are performed in the Power-Up Mode menus and are described below�

IMPORTANT! It is recommended that you power off your amplifiers or turn down their attenuators
before power cycling the iEQ and performing the following Power-Up Mode changes�

To enter, navigate, and edit options within these Power-Up Mode menus, follow these steps:

1. Entering the Power-Up Mode Menus

While applying power to the iEQ, press and hold the CHANNEL 1 button until the following
LED pattern is displayed on the CHANNEL 1 meters:

CHANNEL 1

Power Up Prompt

2. The Menus

System Lockout Menu - To select the System Lockout menu, press and release the CHANNEL 1
button until the CHANNEL 1 -10 LED is lit as shown in the proceeding illustration� Now
press and release the CHANNEL 2 button to toggle through the available options which are
displayed on the CHANNEL 2 OUTPUT LEVEL meter as shown in the proceeding illustration�

System Lockout

Power Up Menu

CHANNEL 1

System Lockout Menu

System Unlocked

System Locked

CHANNEL 2

System Unlocked: When this mode is selected, access to all front panel functions will be

allowed�

System Locked: When this mode is selected, all front panel functions will be locked with

the exception of the INPUT GAIN controls and AFS filter clearing function�

Live Filter Lift Time Menu - To select the Live Filter Lift Time menu, press and release the
CHANNEL 1 button until the CHANNEL 1 0 LED is lit as shown in the proceeding
illustration� Now press and release the CHANNEL 2 button to toggle through the available
options which are displayed on the CHANNEL 2 OUTPUT LEVEL meter as shown in the proceeding
illustration�