DC-DC Switching Regulator

ON/OFF Control

Typical Application Circuit

Fig 1. Remote On/Off with +ve logic used
to turn on or off using a suitable open
collector or open drain function. Turn off is
achived by connecting enable pin to
ground.

Fig 2. Remote On/Off implimentation with
pull up PNP transistor for negative logic
control. Unit is Off when open circuit.

Fig 3. Remote On/Off implimentation
with open collector or open drain
transistor for negative logic control.
Unit is Off when open circuit.

PMQ7250-1 or -2

Typical Characteristics

PMQ7250-1 dissipation with output set to 3.3V DC

PMQ7250-1 dissipation with output set to 5V DC

3