beautypg.com

Newport Brass 2470-5223 User Manual

Page 2

background image

Recommended Installation by a Professional Plumbing Contractor

Note: The use of petroleum base plumbers putty on our products will nullify the warranty. We recom

mend the use of clear silicone sealing materials.

If mounting faucet to stainless steel rim, an under-mount support, (e.g. wood, appropriate size x 1/2”

thick), should be utilized.

1. Drill hole in mounting surface. Recommended deck hole Ø1.350”
not to exceed Ø1.562”.
2. Place O-ring (2) on underside of base RING (1).

See Figure 1a.

3. Insert Hoses through base RING (1) and hole in mounting surface.

Secure into place with MOUNTING KIT (3).

See Figure 1.

4. Attach hot/cold spout supply directly to valves in the wall. See Fig. 2

5.

DO NOT remove the HOSE (6) from SPOUT (4). See Figure 3.

6. Slide WEIGHT(9) onto HOSE(6).

See Figure 4.

7. Connect HOSE (6) to valve outlet (8).

See Figure 4. Attach CLIP (7)

to the connection between HOSE (6) and OUTLET (8).

See Figure 4a.

NWP-2470-5103

Figure 1

Figure 1a

1

3

2

Mounting
surface
hole

Figure 3

6

4

Figure 2

See Detail A

Detail A

DO NOT REMOVE
ZIP TIE

9/16-24 UNEF (FOR 3/8”
COMPRESSION OUTLET )

3/8” COMPRESSION

OUTLET )

REV A

1

4

5

Figure 4

7

8

8

6

9

5

Figure 4a

6