Warning, Af e, Installation to solid concrete or cinder block – Peerless-AV DS-VW665 - Installation User Manual
Page 6
6 of 11
ISSUED: 03-22-12 SHEET #: 125-9288-4 06-25-13
Visit the Peerless Web Site at www.peerless-av.com
For customer care call 1-800-865-2112 or 708-865-8870.
E
F
solid concrete
cinder block
Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
1
CUT
AW
AY
VIEW
INCORRECT
CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
F
Drill holes and insert anchors (
F).
Place
mount assembly (
A)
over anchors (
F) and secure with
screws (
E).
Tighten all fasteners.
A
F
E
concrete
surface
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer
WARNING
Make sure that video mount assembly (
A) is level,
use it as a template to mark four mounting holes.
Drill four 5/16” (8 mm) dia. holes to a minimum
depth of 2.5” (64 mm). Insert anchors (
F) in holes
flush with wall as shown (right). Place video wall
mount assembly over anchors and secure with four
#14 x 2.5” wood screws (
E) and fender washers (G)
as shown below. Level, then tighten all fasteners.
A
G
SIDE VIEW
MOUNTING
SURFACE
SCREEN
DIRECTION
Note: Mount
assembly (
A)
can be installed
to surfaces with
a maximum
angle of 45°.
45°