Installation to Solid Concrete or Cinder Block

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount

in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM

C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a

hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware

and components.

WARNING

1

CUT

AW

AY

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/

dry wall

plaster/

dry wall

concrete

concrete

1

3

2

K

Drill holes and insert anchors (

K).

Place plate (

C) over anchors (K) and secure with screws (I).

Tighten all fasteners.

C

K

I

concrete

surface

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to

concrete covered with plaster, drywall, or other

finishing material. If mounting to concrete surfaces

covered with a finishing surface is unavoidable (not

evaluated by UL), the finishing surface must be

counterbored as shown below. Be sure concrete

anchors do not pull away from concrete when

tightening screws. If plaster/drywall is thicker than

5/8" (16 mm), custom fasteners must be supplied

by installer (not evaluated by UL).

WARNING

Make sure that wall plate (

C) is level, use it as a

template to mark four mounting holes. The top mounting

hole should be 2.5" (64 mm) above the desired screen

center as shown in figure 1.1 on page 4. Drill four 5/16"

(8 mm) dia. holes to a minimum depth of 2.5" (64 mm).

Insert anchors (

K) in holes flush with wall as shown

(right). Place wall plate over anchors and secure with

#14 x 2.5" screws (

I). Level, then tighten all fasteners.