Warning, Ah i, Hi a – Peerless-AV PANA-85WM - Installation User Manual
Page 5: Installation to solid concrete or cinder block, Fig. 1.1 fig. 1.2
5 of 8
ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
solid concrete
cinder block
Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
1
CUT
AW
AY
VIEW
INCORRECT
CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
H
Drill holes and insert anchors (
H).
Place plate (
A) over anchors (H) and secure with screws (I).
Tighten all fasteners.
A
H
I
concrete
surface
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer.
WARNING
Make sure that wall plate (
A) is level, use it as a
template to mark nine mounting holes. Drill nine 5/16"
(8 mm) dia. holes to a minimum depth of 2.5" (64 mm).
Insert anchors (
H) in holes flush with wall as shown in
figure 1.1. Place wall plate over anchors and secure
with nine #14 x 2.5" screws (
I). Level, then tighten all
fasteners as shown in fig. 1.2.
H
I
A
Fig. 1.1