beautypg.com

Warning, Cbb aa d d bb aa c, Aa d – Peerless-AV PRG-EXC-W - Installation User Manual

Page 7

background image

7 of 14

ISSUED: 04-24-08 SHEET #: 055-9257-7 07-15-11

Visit the Peerless Web Site at www.peerlessmounts.com

For customer care call 1-800-865-2112

Installation to Concrete Ceilings or Concrete/Cinder Block Walls

NOTE: Wall installation with models PRG-EXC,
PRG-EXC-S and PRG-EXC-W is not available.

Place ceiling/wall plate (AA) on ceiling or wall as a
template. Note: Place ceiling/wall plate according
to position of opening in outer channel (BB) as
shown in fi gure 2.4. or fi gure 2.5. Drill two 5/16"
(8mm) dia. holes to a minimum depth of 2-1/2"
(64 mm). Attach ceiling/wall plate (AA) using two
concrete anchors (C), two #14 x 2-1/2" wood
screws (D) and two 1/4" washers (F) as shown in
fi gure 2.6. Tighten wood screws (D) until ceiling/
wall plate (AA) is fi rmly attached.

2

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete

thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifi ca-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all at-

tached hardware and components.

WARNING

C

BB

AA

D

D

BB

AA

C

OPENING ON OUTER

CHANNEL (BB) INDICATES

FRONT OF MOUNT

CONCRETE
CEILING

CONCRETE
WALL

CINDER
BLOCK
WALL

OPENING ON
OUTER CHANNEL
(BB) INDICATES
TOP OF MOUNT

fi g. 2.4

fi g. 2.5

CEILING
INSTALLATION

WALL INSTALLATION

(EXCEPT FOR EXC MODELS)

F

F

1

3

2

C

C

Drill holes and insert anchors (C).

Place plate (AA) over anchors (C) and secure with screws (D).

Tighten all fasteners.

AA

D

concrete
surface

• Always attach concrete anchors directly to load-

bearing concrete.

• Never attach concrete anchors to concrete covered

with plaster, drywall, or other fi nishing material.
If mounting to concrete surfaces covered with a
fi nishing surface is unavoidable (not evaluated by
UL), the fi nishing surface must be counterbored
as shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8", custom fasteners
must be supplied by installer (not evaluated by UL).

WARNING

• Tighten wood screws fi rmly, but do not overtighten.

Overtightening can damage the screws, greatly
reducing their holding power.

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

CUT

A

W

A

Y

VIEW

CORRECT

plaster/
dry wall

concrete

INCORRECT

plaster/
dry wall

concrete

AA

AA

fi g.
2.6