ceiling plate (not included)
Thread support pipe (schedule 40 pipe, 1.5 x 11.5 NPT, not included) into threaded fitting in ceiling plate
(UL Listed CMJ470, not included). Tighten - four or five complete turns - leaving slot aligned with one small hole in
the side of the ceiling plate threaded fitting. Insert and tighten one M5 x .8 x 10 mm penta-pin screw (E) provided
with ceiling plate as shown. Use the M5 penta-pin tool (I) to tighten screw. BY HAND, insert four M10 x 1.5 x 15
mm penta-pin screws (G) into threaded holes in the sides of ceiling arm box (A). Leave approximately 1/4" of
exposed thread. Slide ceiling arm box (A) and fiber washer (F) onto end of support pipe. Thread retaining collar (D)
onto threaded end of support pipe. Tighten - four or five complete turns. Slide ceiling arm box (A) down so that it
is on top of retaining collar (D). Insert and tighten one M5 x .8 x 10 mm penta-pin screw (E) into retaining collar (D)
as shown. Insert one M5 penta-pin screw (E) through the tab on the back of ceiling arm box (A). Use M5 penta-
pin tool (I) to tighten screw just enough to stabilize support pipe.
Note: UL Listed ADJ or EXT extension column series can be used in combination with, or in place of support
pipe to achieve different lengths.