Warning, Ef g, Af e – Peerless-AV DS-VW765-LAND - Installation User Manual
Page 6
6 of 13
ISSUED: 2013-05-13 SHEET #: 145-9011-9 2013-06-25
E
F
G
SOLID CONCRETE
CINDER BLOCK
Installation to Solid Concrete or Cinder Block
1
1
3
2
F
Drill holes and insert anchors (
F).
Place plate (
A) over anchors (F) and secure with screws (E).
Tighten all fasteners.
A
F
E
concrete
surface
NOTE: Make sure that there is a minimum of 16"
horizontal distance between #14 x 2.5
"
screws (
E).
Make sure that pull-out mount assembly (
A) is level,
use it as a template to mark four mounting holes. Drill
four 5/16" (8 mm) dia. holes to a minimum depth of
2.5" (64 mm). Insert anchors (
F) in holes flush with
wall as shown (right). Place pull-out mount assembly
(
A) over anchors and secure with four #14 x 2.5"
screws (
E), and fender washers (G). Level, then
tighten all fasteners.
A
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material.
WARNING
• When installing Peerless wall mounts on a concrete wall, the wall must be at least 8
"
thick with a minimum compres-
sive strength of 2000 psi.
• When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specifications
and have a minimum nominal width of 8
"
. Do not drill into mortar joints! Be sure to mount in a solid part of the block,
generally 1
"
(25 mm) minimum from the side of the block. It is suggested that a standard electric drill on slow setting
is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or
cavity.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING