background image

ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10

Visit the Peerless Web Site at www.peerlessmounts.com

5 of 9

For customer care call 1-800-729-0307 or 708-865-8870.

Drill two 1/4" (6 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach ceiling plate (Y)
using two concrete anchors (V) and #14 x 2.5"
wood screws (U) as shown in Illustration A and
1
, 2, and 3 (below). Tighten all fasteners.

Skip to step 2

• When installing Peerless wall mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete

surface in the 1/4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must
meet ASTM C-90 specifi cations.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the supporting surface will safely support the combined load of the equipment and all attached

hardware and components.

• Never exceed the Maximum UL Load Capacity.

WARNING

• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to con-

crete covered with plaster, drywall, or other fi nishing
material. If mounting to concrete surfaces covered
with a fi nishing surface is unavoidable (not evaluated
by UL), the fi nishing surface must be counterbored
as shown below. If plaster/drywall is thicker than
5/8", custom fasteners must be supplied by installer
(not evaluated by UL).

WARNING

Illustration A

U

Y

CONCRETE CEILING

V

1

Installation to Concrete Ceilings

• Tighten wood screws so that ceiling plate is fi rmly

attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

concrete
surface

1

3

2

V

Drill holes and insert anchors (V).

Place plate (Y) over anchors (V) and secure with screws (U).

Tighten all fasteners.

Y

V

U

CUT

A

W

A

Y

VIEW

INCORRECT

CORRECT

plaster/

dry wall

concrete

concrete

plaster/

dry wall

Y

Y

U