beautypg.com

Specifications – B&B Electronics MESP211D_T - Datasheet User Manual

Page 2

background image


www.bb-elec.com [email protected] [email protected]

International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104

European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445





























Approvals / Certifications

Emissions

FCC Class B, CISPR Class A (EN55022)

CE

EN61000-6-2:2005

(Heavy Industrial)

EN61000-4-2:2008

(ESD)

+/-8kV Contact, +/-15kV Air

EN61000-4-3:2006

(RI)

10V/m, 80-1000MHz; 3V/m, 1.3 to 2.7 GHz

EN61000-4-4:2004

(EFT Burst)

+/-2kV DC ports; +/-1kV signal ports

EN61000-4-5:2005

(Surge)

+/- 0.5 kV DC Ports, +/- 1 kV Signal Ports

EN61000-4-6:2005

(CI)

10 VRMS, 0.15 to 80 MHz

EN61000-4-8:2001

(Magnetic)

10A/m, 50Hz & 60Hz

Shock

IEC60068-2-27

50G peak, 11ms, 3 axes

Vibration

IEC60068-2-6

10-500Hz, 4G, 3 axes

Freefall (Drop)

IEC60068-2-32

10 total drops from sides, corner and edges, 1M

Specifications

Serial Technology

RS-232 (DB9)

TD, RD, DTR, DSR, RTS, CTS, DCD, Signal Ground

RS-232 (Terminal Block)

TD, RD, RTS, CTS, Signal Ground

RS-485 2-Wire

Data A(-), Data B(+), GND

RS-422/485 4-Wire

TDA(-), TDB(+), RDA(-), RDB(+), GND

Serial Connector

DB9M or Removable Terminal Blocks

Data Rate

Up to 230.4 Kbps

Protocols

Protocols

TCP, IPv4, UDP, ARP, HTTP 1.0, ICMP/PING, DHCP/BOOTP

IP Mode

Static, DHCP

TCP/UDP
UDP

User definable
Unicast or Multicast

Other

Connection Mode

MODBUS RTU Master / Slave, MODBUS ASCII Master/Slave

Search

Serial direct COM and Ethernet Auto Search or specific IP

Diagnostics

Display PC IP, ping, save test config (text readable)

Firmware Upgrade

Firmware can be updated through the manager software

Modbus Monitor

The Manager Software has a Modbus Monitor feature

Configuration Software

OS Compatibility

XP (32/64), Vista (32/64), Windows 7 (32/64), Windows 8 (32/64), Server 2003 (32/64), Server 2008 (32/64),
Server 2012 (64)