beautypg.com

B&B Electronics 860-12100 - Manual User Manual

Page 8

background image

5

Unmanaged Modules

Before installing, configure the iMcV-10G-Converter modules for desired features.
The DIP Switch settings enable the end user to select the speed/protocol, loopback
modes and Loss Carry Forward (LCF). The table below indicates the available features
and settings for the iMcV-10G-Converter modules.

Switch

Function

Default

1

“ON” to Enable LOS from XFP1 to XFP2

OFF

2

“ON” to Enable LOS from XFP2 to XFP1

OFF

5

4

3

Combination of settings

OFF

OFF OFF

Use Internal clock

OFF

ON

OFF

OC-192 SONET/SDH (9.95 Gb/S)

OFF

OFF ON

10G Ethernet (10.32 Gb/S)

OFF

ON

ON

10G Fibre Channel (10.52 Gb/S)

ON

OFF OFF

ITU G-709 OUT-2 (10.70)

ON

OFF ON

10G Ethernet G.702 (11.09Gb/S)

ON ON OFF





5,4,3

ON ON ON

N.A. (default 0,0,0)



OFF/OFF/

OFF

(Ethernet)

6

“ON” to enable FAULT on DDMI alarm

OFF

7

Enable Loopback XFP1

OFF

8

Enable Loopback XFP2

OFF