beautypg.com

B&B Electronics 102MC-FL_SC_ST - Manual User Manual

Page 8

background image

(Revised 8/5/2009)

8

DIN-Rail Mounting

Install the unit in a standard DIN rail. Recess the unit to allow at least 2” of horizontal clearance for CAT5e
cable bend radius.


To install the unit to 35mm industrial DIN rail,
place the top edge of the included mounting
bracket on the back of the unit against the DIN
rail at a 15° angle as shown. Rotate the bottom of
the unit to the back (away from you) until it
snaps into place.

To remove the unit from the 35mm industrial
DIN rail, place a flat head screwdriver into the
release clip found at the bottom of the unit, and
apply downward force on the clip until it
disengages from the bottom of the unit from the
DIN rail. Rotate the bottom of the unit towards
you and up at an approximate 15° upward angle
to completely remove the unit.





Most N-Tron™ products are

designed to be mounted on industry
standard 35mm DIN rail. However,
DIN rail mounting may not be
suitable for all applications. Our
Universal Rack Mount Kit (P/N:
URMK) may be used to mount the
100 Series enclosures to standard 19"
racks as an option.