Functional Description

(Continued)

Extended Repetitive Interrupt Mode is shown in

Figure 14

and operates in the following way: Once activated, all inter-
rupts remain activated until reset by a read of the Interrupt
Status Register 1. Once activated all T_CRIT_A interrupts
remain activated until reset by a read of the Extended Mode
Register 1. Temperature conversion data less than or equal
to T

LOW

will activate interrupt. Interrupt will continue to be

activated until the temperature data exceeds (T

LOW

+

T

HYST

). Exceeding T

HIGH

activates interrupt. Interrupt will

continue to be activated at the end of a conversion until the
temperature data is less than or equal to (T

HIGH

− T

HYST

).

T_CRIT_A interrupts are activated when the temperature
exceeds T_CRIT. T_CRIT_A interrupts will no longer be
activated if the temperature data at the end of a conversion
is less than or equal to( T_CRIT − T

HYST

).

Extended One-Time Interrupt Mode is shown in

Figure 15

and operates in the following way: Once activated all inter-
rupts remain activated until reset by a read of the Interrupt
Status Register 1. Once activated all T_CRIT_A interrupts
remain activated until reset by a read of the Extended Mode
Register 1. An interrupt will be activated when the data of a
temperature conversion is less than or equal to T

LOW

. Inter-

rupt cannot again be activated until the data from a tempera-
ture conversion is greater than (T

LOW

+ T

HYST

). An interrupt

will be activated when the data of a temperature conversion
is greater than T

HIGH

. Interrupt cannot again be activated

until the data of a temperature conversion is less than or
equal to (T

HIGH

− T

HYST

). T_CRIT_A interrupt is activated

when the data from a temperature conversion is greater than
T_CRIT. Activation of an T_CRIT_A interrupt cannot occur
until the data from a temperature conversion is less than or
equal to ( T_CRIT − T

HYST

).

Extended Comparator Mode is shown in

Figure 16 and

operates in the following way: Interrupt is activated when the
data from a temperature conversion is less than or equal to
T

LOW

. Interrupt is reset when the data from a temperature

conversion exceeds (T

LOW

+ T

HIGH

). Exceeding T

HIGH

will

activate interrupt. This interrupt will be reset when data from
a temperature conversion is less than or equal to (T

HIGH

T

HYST

). T_CRIT_A interrupt is activated when the tempera-

ture exceeds T_CRIT. T_CRIT_A remains active until the
data from a temperature conversion is less than or equal to
(T_CRIT − T

HYST

) resets it.

DS100072-20

*

Note: Interrupt resets occur only when interrupt Status Register 1 is read.

FIGURE 14. Extended Repetitive Interrupt Mode

DS100072-21

*

Note: Interrupt resets occur only when interrupt Status Register 1 is read.

FIGURE 15. Extended One-Time Interrupt

DS100072-19

*

Note: Interrupt resets occur only when interrupt Status Register 1 is read.

FIGURE 16. Extended Comparator Mode