1.0 Functional Description

(Continued)

1.12 Fault Queue

In order to suppress erroneous ALERT or T_CRIT triggering
the LM86 incorporates a Fault Queue. The Fault Queue acts
to insure a remote temperature measurement is genuinely
beyond a HIGH, LOW or T_CRIT setpoint by not triggering
until three consecutive out of limit measurements have been
made, see Figure 10. The fault queue defaults off upon
power-up and may be activated by setting bit D0 in the
Configuration register (09h) to “1”.

1.13 One-Shot Register

The One-Shot register is used to initiate a single conversion
and comparison cycle when the device is in standby mode,
after which the device returns to standby. This is not a data
register and it is the write operation that causes the one-shot
conversion. The data written to this address is irrelevant and
is not stored. A zero will always be read from this register.

2.0 LM86 REGISTERS

2.1 COMMAND REGISTER

Selects which registers will be read from or written to. Data for this register should be transmitted during the Command Byte of
the SMBus write communication.

P7

P6

P5

P4

P3

P2

P1

P0

Command Select

P0-P7: Command Select

Command Select Address

Power On Default State

Register

Name

Register Function

Read Address

<

P7:P0

>

hex

Write Address

<

P7:P0

>

hex

<

D7:D0

>

binary

<

D7:D0

>

decimal

00h

NA

0000 0000

0

LT

Local Temperature

01h

NA

0000 0000

0

RTHB

Remote Temperature High Byte

02h

NA

0000 0000

0

SR

Status Register

03h

09h

0000 0000

0

C

Configuration

04h

0Ah

0000 1000

8 (16 conv./sec)

CR

Conversion Rate

05h

0Bh

0100 0110

70

LHS

Local HIGH Setpoint

06h

0Ch

0000 0000

0

LLS

Local LOW Setpoint

07h

0Dh

0100 0110

70

RHSHB

Remote HIGH Setpoint High

Byte

08h

0Eh

0000 0000

0

RLSHB

Remote LOW Setpoint High

Byte

NA

0Fh

One Shot

Writing to this register will

initiate a one shot conversion

10h

NA

0000 0000

0

RTLB

Remote Temperature Low Byte

10130330

FIGURE 10. Fault Queue Temperature Response

Diagram

LM86

www.national.com