Rainbow Electronics MAX1068 User Manual
Page 6
MAX1067/MAX1068
Multichannel, 14-Bit, 200ksps Analog-to-Digital
Converters
6
_______________________________________________________________________________________
TIMING CHARACTERISTICS (Figures 1, 2, 8, and 16)
(AV
DD
= +4.75V to +5.25V, DV
DD
= +2.7V to +5.25V, f
SCLK
= 4.8MHz external clock (50% duty cycle), 24 clocks/conversion
(200ksps), external V
REF
= +4.096V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Acquisition Time
t
ACQ
External clock (Note 6)
729
ns
SCLK to DOUT Valid
t
DO
C
DOUT
= 30pF
100
ns
CS Fall to DOUT Enable
t
DV
C
DOUT
= 30pF
100
ns
CS Rise to DOUT Disable
t
TR
C
DOUT
= 30pF
80
ns
CS Pulse Width
t
CSW
100
ns
SCLK rise
CS to SCLK Setup
t
CSS
SCLK fall (DSP)
100
ns
SCLK rise
CS to SCLK Hold
t
CSH
SCLK fall (DSP)
0
ns
Conversion
93
SCLK High Pulse Width
t
CH
Duty cycle 45% to 55%
Data transfer
93
ns
Conversion
93
SCLK Low Pulse Width
t
CL
Duty cycle 45% to 55%
Data transfer
93
ns
SCLK Period
t
CP
209
ns
SCLK rise
DIN to SCLK Setup
t
DS
SCLK fall (DSP)
100
ns
SCLK rise
DIN to SCLK Hold
t
DH
SCLK fall (DSP)
0
ns
CS Falling to DSPR Rising
t
DF
100
ns
DSPR to SCLK Falling Setup
t
FSS
100
ns
DSPR to SCLK Falling Hold
t
FSH
0
ns
Note 1: AV
DD
= DV
DD
= +5.0V.
Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after full-scale range has been
calibrated.
Note 3: Offset and reference errors nulled.
Note 4: DC voltage applied to on channel, and a full-scale 1kHz sine wave applied to off channels.
Note 5: Conversion time is measured from the rising edge of the 8th external SCLK pulse to EOC transition minus t
ACQ
in 8-bit data-
transfer mode.
Note 6: See Figures 10 and 17.
Note 7: f
SCLK
= 4.8MHz, f
INTCLK
= 4.0MHz. Sample rate is calculated with the formula f
s
= n
1
(n
2
/ f
SCLK
+ n
3
/ f
INTCLK
)-1 where: n
1
= number of scans, n
2
= number of SCLK cycles, and n
3
= number of internal clock cycles (see Figures 11–14).
Note 8: Internal reference and buffer are left on between conversions.
Note 9: Defined as the change in the positive full scale caused by a ±5% variation in the nominal supply voltage.