DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication

Table 12. Guide to Function Command Requirements

COMMAND

ISSUE MEMORY

ADDRESS

ISSUE 00h

BEFORE READ

READ/WRITE

TIME SLOTS

Write Challenge

Write: 64

Compute MAC

Yes

Read: up to 160

Compute Next Secret

Clear/Lock Secret, Set/Clear
Overdrive

— — —

Read Data

8 bits

Read: up to 2048

Write Data

8 bits

Write: up to 2048

Copy Data

8 bits

Recall Data

8 bits

Lock 8

bits

Reset —


Figure 9. Compute MAC Function Command

35 of 38