ABSOLUTE MAXIMUM RATINGS*

Voltage on any pin relative to ground

–0.5V to +6.0V

Operating temperature

–55

°

C to +100

°

C

Storage temperature

–55

°

C to +125

°

C

Soldering temperature

See J-STD-020A Specification


*These are stress ratings only and functional operation of the device at these or any other conditions

above those indicated in the operation sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods of time may affect reliability.

DC ELECTRICAL CHARACTERISTICS

(-55°C to +100°C; V

PU

=3.0V to 5.5V)

PARAMETER SYMBOL

CONDITION

MIN

TYP

MAX

UNITS

NOTES

Pullup Supply
Voltage

V

PU

3.0

5.5

V

1,2

Thermometer Error

t

ERR

-10°C to +85°C

±2

°C

3

-55°C to +100°C

±3

Input Logic Low

V

IL

-0.3

+0.8

V

1,4,5

Input Logic High

V

IH

3.0

5.5

V

1,6

Sink Current

I

L

V

I/O

=0.4V 4.0

mA 1

Active Current

I

DQA

1

1.5

mA

7

DQ Input Current

I

DQ

5

µA

8

Drift

±0.2 °C

9

NOTES:

1. All voltages are referenced to ground.
2. The Pullup Supply Voltage specification assumes that the pullup device (resistor or transistor) is

ideal, and therefore the high level of the pullup is equal to V

PU

. In order to meet the V

IH

spec of the

DS1822-PAR, the actual supply rail for the strong pullup transistor must include margin for the
voltage drop across the transistor when it is turned on; thus: V

PU_ACTUAL

= V

PU_IDEAL

+ V

TRANSISTOR

.

3. See typical performance curve in Figure 15.
4. Logic low voltages are specified at a sink current of 4 mA.
5. To always guarantee a presence pulse under low voltage parasite power conditions, V

ILMAX

may have

to be reduced to as low as 0.5V.

6. Logic high voltages are specified at a source current of 1 mA.
7. Active current refers to supply current during active temperature conversions or EEPROM writes.
8. DQ line is high (“hi-Z” state).
9. Drift data is based on a 1000 hour stress test at 125°C.

AC ELECTRICAL CHARACTERISTICS: NV MEMORY

(-55°C to +100°C; V

PU

=3.0V to 5.5V)

PARAMETER SYMBOL

CONDITION

MIN

TYP

MAX

UNITS

NV Write Cycle Time

t

wr

2

10

ms

EEPROM Writes

N

EEWR

-55°C to +55°C

50k

writes

EEPROM Data Retention

t

EEDR

-55°C to +55°C

10

years