beautypg.com

Ds18s20 function command set table 4, Memory commands, Notes – Rainbow Electronics DS18S20 User Manual

Page 11

background image

DS18S20

11 of 21

DS18S20 FUNCTION COMMAND SET Table 4

Command

Description

Protocol

1-Wire Bus Activity

After Command is Issued

Notes

TEMPERATURE CONVERSION COMMANDS

Convert T

Initiates temperature
conversion.

44h

DS18S20 transmits conversion
status to master (not applicable
for parasite-powered DS18S20s).

1

MEMORY COMMANDS

Read Scratchpad Reads the entire scratchpad

including the CRC byte.

BEh

DS18S20 transmits up to 9 data
bytes to master.

2

Write Scratchpad Writes data into scratchpad

bytes 2 and 3 (T

H

and T

L

).

4Eh

Master transmits 2 data bytes to
DS18S20.

3

Copy Scratchpad Copies T

H

and T

L

data from

the scratchpad to EEPROM.

48h None

1

Recall E

2

Recalls T

H

and T

L

data from

EEPROM to the scratchpad.

B8h

DS18S20 transmits recall status
to master.

Read Power
Supply

Signals DS18S20 power
supply mode to the master.

B4h

DS18S20 transmits supply status
to master.

NOTES:

1. For parasite-powered DS18S20s, the master must enable a strong pullup on the 1-wire bus during

temperature conversions and copies from the scratchpad to EEPROM. No other bus activity may take
place during this time.

2. The master can interrupt the transmission of data at any time by issuing a reset.
3. Both bytes must be written before a reset is issued.