beautypg.com

Max5176, Typical operating characteristics (continued), Pin description – Rainbow Electronics MAX5176 User Manual

Page 9

background image

MAX5174/MAX5176

Low-Power, Serial, 12-Bit DACs

with Voltage Output

_______________________________________________________________________________________

9

Typical Operating Characteristics (continued)

(MAX5174: V

DD

= +5V, V

REF

= 2.5V; MAX5176: V

DD

= +3V, V

REF

= +1.25V; C

L

= 100pF, OS = AGND, code = FFF hex,

T

A

= +25°C, unless otherwise noted.)

SCLK

2V/div

OUT

500

µ

V/div

2

µ

s/div

DIGITAL FEEDTHROUGH (SCLK, OUT)

MAX5174/6 toc26

AC-COUPLED

-30

-15

-20

-25

-5

-10

0

5

0

1000

1500

500

2000

2500

3000

REFERENCE INPUT

FREQUENCY RESPONSE

MAX5174/6toc27

FREQUENCY (kHz)

GAIN (dB)

V

REF

= 0.67Vp-p + 0.75V

DC

50ms/div

START-UP GLITCH

V

OUT

10mV/div

AC-COUPLED

MAX5174/6 toc28

V

DD

1V/div

MAX5176

Pin Description

Voltage Output. High impedance when in shutdown. The output voltage is limited to V

DD

.

OUT

2

Power-Down Lockout. (digital input). Connect to V

DD

to allow shutdown. Connect to DGND to disable

software and hardware shutdown.

PDL

4

Reset Mode Select (digital input). Connect to V

DD

to select midscale reset output voltage. Connect to

DGND to select 0 reset output voltage.

RS

3

Chip-Select Input (digital input). DIN ignored when CS is high.

CS

6

Serial Clock Input (digital input).

SCLK

8

Serial-Data Input (digital input). Data is clocked in on the rising edge of SCLK.

DIN

7

Clear DAC. (digital input) Clears the DAC to either zero or midscale as determined by RS.

CLR

5

Serial-Data Output

DOUT

10

Shutdown (digital input). Pulling SHDN high when PDL = V

DD

places the chip in shutdown with a maximum

shutdown current of 10µA.

SHDN

12

User-Programmable Output. State is set by the serial input.

UPO

11

Reference Input. Maximum V

REF

is V

DD

- 1.4V.

REF

14

PIN

Positive Supply. Bypass to AGND with a 4.7µF capacitor in parallel with a 0.1µF capacitor.

V

DD

16

Offset Adjustment. Connect to AGND for no offset.

OS

1

FUNCTION

NAME

No Connection

N.C.

15

Analog Ground

AGND

13

Digital Ground

DGND

9