Timing Diagrams

The following diagram shows the general clocking scheme for TH7815ACC.

The line is composed as follows:

Postscan elements may be added in order to either increase the exposure time, or to
provide a voltage reference level.

Figure 1. Line Timing Diagram

The following diagram shows the timing for the transfer period:

Figure 2. Line Transfer Period

Φ

R clock may also be held in high state during line transfer period.

Synopsis

Number of Prescan

Pixels Per Output

Number of Useful
Pixels Per Output

Total Number of Pixels

Per Output

TH7815ACC

4

2048

2052

Φ

A

P

Φ

L1

Φ

L2

Φ

R

Φ

Line Period

Transfer Period

Φ

A

P

Φ

L1

Φ

L2

Φ

R

Φ

> 300 ns

> 10 ns

> 10 ns

first prescan pixel

(700 ns typ.)