Operating Conditions (T = 25°)

Notes:

1. Nominal value of V

T

:

V

TN

= 6.7V if

Φ

T

clock levels are at their typical value.

2. No use for operation. For testing purpose only.

Basic Internal
Configuration

Note:

1. Make the straps as short as possible to avoid any parasitic coupling to these connections. The load capacitance introduced

by the strap should not exceed 5 pF.

Table 1. DC Bias Characteristics

Parameter

Symbol

Value

Unit

Remark

Min.

Typ.

Max

Output Amplifier Drain Supply

V

DD

14

15

16

V

Reset DC Bias

V

DR

V

DD

- 2.4

V

DD

- 2

V

DD

- 1

V

Output Gate DC Bias

V

GS

5.5

6

6.5

V

Photosensitive Zone And
Register DC Bias

V

T

0.95 V

TN

V

TN

1.05 V

TN

V

(1)

Substrate Bias

V

SS

0.0

0.0

V

Test Point 1

TP1

V

DD

V

(2)

Tests Points 2 And 3

TP2, TP3

V

SS

V

(2)

V

TN

V

ΦT

(

)HIGH

V

ΦT

(

)LOW

+

2

----------------------------------------------------------------------

5%

±

=

S

Φ

ECHA

and

Φ

RA

internal to TH7804A

S

Φ

ECHB

and

Φ

RA

Table 2. Selection of Nominal Mode

Option

Implementation

Remarks

Internal Sampling

V

INH

(19) Connected to V

SS

S

Φ

ECHA

(3) and

Φ

ECHA

(2) Strapped

S

Φ

ECHB

(21) and

Φ

ECHB

(22) Strapped

(1)

see note

Internal Reset

Φ

RA

(4) and

Φ

RB

(18) Connected to V

DD