Wire connections, Specifications – Electronics 500-24 User Manual
Page 6
6
Note:
The MagnaValve is designed
to operate vertically must be mount-
ed within 5 degrees of vertical.
1
2
3
4
5
6
1. WHITE
2. RED
3. GREEN
4. ORANGE
5. BLACK
6. BLUE
NOTE:
Make connection from power
supply directly to the Magna-
Valve to prevent high current
voltage drops.
Use 16 AWG or larger wire size
for connection to the controller.
Be sure Power supply is regu-
lated and capable of 4Amp
(100VA) output.
FC-24 500-24
6. PROCESS IN 0-10V
1. WHITE 0-10VDC OUT
5. PROCESS 0VDC
3. GREEN 0VDC
8. SERVO OUT
4. ORANGE 0-10VDC IN
9. VALVE ENABLE
6. BLUE 24VDC ENABLE
19. 24VDC SUPPLY
2.RED 24VDC SUPPLY
20. 0V COMMON
5. BLACK 0V COMMON
WIRE CONNECTIONS
Valve ON
Vin >.25Vdc
24Vdc Enable
24Vdc Power
ZERO (Factory set)
SPAN (Factory set)
FRONT VIEW COVER REMOVED
Pulse Rate
(Factory set)
See FC-24 Data Sheet for more information
Laptop computer port for calibration
SPECIFICATIONS
Input
Enable: 24Vdc
Flow Command: 0-10Vdc
Power:
24Vdc @ 4A (100VA)
Adjustments
Zero, Span, Pulse Rate
Flow Signal:
0-10Vdc
Accuracy:
±1% (of Full Scale)*
Flow Range:
120-1200 lb/min**
Media:
Steel or Cut wire Shot
Mode: Normally
closed
Temp Range:
40 -110 F (5 - 43 C)
Output