FC Controller (sold separately)
Flow Sensor Input
from MagnaValve
0 - 5 Vdc into 100K
Flow Enable Input
120 Vac
Servo Command Output
PWM 50 Vdc*
Remote Setpoint Input
0 - 10 Vdc
120 Vac Series MagnaValve
Magnetic Media Valve for Air Blast Machines
Electronics Inc.
56790 Magnetic Drive
Mishawaka, Indiana 46545 USA
(574)256-5001
120 VacMagnaValveRev2 06/11
Specification is subject to change without notice
Valve Specifications
Power
from FC Controller
±12 Vdc @ 100 mA maximum
Media
All ferrous media except
Cast Stainless Steel
Maximum Pressure
100 PSI
Mode
Normally Closed
Temperature Range
32 - 122º F (0 -50º C)
Servo Command Input
PWM 50 Vdc*
0 - 10
24 Vdc
Flow Sensor Output
0 - 5 Vdc
0 - 10 Vdc
Top View
Side View
Model Number
Pipe Size
“A”
“B”
“C”
“D”
“E”
“F”
“G”
578
1.25 “ NPT
7.3” (185 mm)
3.5” (88.9 mm)
4.5” (114.3 mm)
2.0” (50.8 mm)
3.1” (78.8 mm)
3.0” (76.2 mm)
6.0” (152.4 mm)
579
1.25 “ NPT
7.3” (185 mm)
3.5” (88.9 mm)
4.5” (114.3 mm)
4.0” (101 mm)
3.1” (78.8 mm)
3.0” (76.2 mm)
8.0” (203.2mm)
580
2.0 “ NPT
8.4” (214 mm)
4.0” (101.6 mm)
5.5” (139.7 mm)
3.5” (88.9 mm)
3.5” (88.9 mm)
3.5” (88.9 mm)
8.0” (203.2mm)
590
2.0 “ NPT
8.4” (214 mm)
4.0” (101.6 mm)
5.5” (139.7 mm)
3.5” (88.9 mm)
3.5” (88.9 mm)
3.5” (88.9 mm)
8.0” (203.2mm)
4.9’’
(124 mm)
“B’’
“D’’
“E’’
“F’’ “G’’
“A”
“C”
* PWM - Pulse Width Modulation 8 Hertz frequency with 0-100% duty cycle, 50Vdc power signal