Magnavalve specifications, Remote valve driver display leds, Dimensions – Electronics WM 3000-24 User Manual
Page 2

WM 3000-24 MagnaValve®
Magnetic Media Valve for Wheel Blast Machines
Electronics Inc.
56790 Magnetic Drive
Mishawaka, Indiana 46545 USA
(574)256-5001
Specification is subject to change without notice
Rev 4/13
MagnaValve is a registered trademark of Electronics Inc.
MagnaValve Specifications
Power
+24 Vdc @ 2 A (50 VA)
Media
Steel Shot and Grit
Weight
32 lb (14.5 kg)
Mode
Normally Closed
Temperature Range Valve: 50˚- 230˚ F (10˚-110˚ C)
Valve Driver: 50˚- 120˚ F (10˚- 49˚ C)
Signal Input
0 - 10 Vdc
1
Flow Rate
0 - 3,000 lb/min (0 - 1,361 kg/min)
1
.91”
(23 mm)
9.30”
(236 mm)
4.50”
(114 mm)
1.50”
(38 mm)
1.50”
(38 mm)
.56”
(14 mm)
10.00”
(254 mm)
9.00”
(229 mm)
2.87”
(73 mm)
4.29”
(109 mm)
07.13”
(181 mm)
05.00”
(127 mm)
5.54”
(141 mm)
5.00”
(127 mm)
6.50”
(165 mm)
4.75”
(121 mm)
4.25”
(108 mm)
For flow rate stability, the MagnaValve should be located as
close as possible (within 3 ft / 1 m) to the blast machine wheel
Remote Valve Driver Display LEDs
Valve On
0 - 10 Vdc Command Input Available
24 V Flow Enable
+24 Vdc Power
Dimensions
Two 6 ft cables with 6-pin plugs come with the WM 3000-24
and Remote Valve Driver. One cable connects the WM 3000-24
and Remote Valve Driver; the other cable connects the
Remote Valve Driver to the AC-24 Controller.
The Remote Valve Driver must be installed in electrical panel.
1
Transfer function (input signal to output flow) is non-linear. AC-24 Controller must be used for proper closed loop
servo capability based on wheel amps.