6. Installation
PNEG-1094 Farm Grain Bin - 4" Corrugation
47
2 Ring Door Installation
Before starting to install, be sure the correct door has been received.
Note that
1 ring doors are standard with some sizes of bins/silos. Refer to
for round access door
installation instructions.
2 Ring Door Installation Instructions
1. Remove inner door panels (19-21) and outer door cover (1). Apply double row of rope caulk along
door flanges, noting how door and bin sheets lap. The top of the door frame goes to the inside of
the sidewall and the bottom of the door frame goes to the outside of the sidewall sheet. With inner
door panels and outer door cover removed, set door frame into opening. Insert a bolt at the four (4)
corners of door frame and sidewall, but do not tighten until completing
.
2. Re-install inner door panels (19-21) at original locations. Close latch bars (12) to lock panels in place.
Be sure that panels are fully seated over all bearing pins (17). Install inner panel hinge assemblies
(8-10) per illustration instructions with hinges.
NOTE: Do not distort door frame with use of alignment or drift punches - if necessary, drill or ream
holes to insert bolts in door frame. Now tighten frame bolts starting at center and working
toward top and bottom on each side.
3. Keep inner panels latched and loosen all bearing pin bolts (17). Re-tighten all bearing pin bolts. This
makes loading on pins uniform for easier operation of panels.
4. If some latch bars (12) are loose or require excessive force to lock, loosen hex socket cap screws
and adjust in or out until latch bars operate smoothly. Check that the panels are fully seated over all
bearing pins.
5. Re-install outer door cover (1). Adjust outer door hinges and latches as required.
6. Assemble door hold back as shown in
. Open door cover (1) until it approaches
the bin wall. Hook retaining bracket (5) over lower latch (2) mount and position the door hold back
bracket (24) against bin wall in a valley. Drill a 3/8" hole through the bin wall and bolt the door hold
back bracket (24) to the bin. If needed, install the door hold back extension (25) to door hold back
bracket (24).
Figure 6U 2 Ring Door Installed
4.00" Corrugation
WD-6241
12'-27' Bins/Silos
WD-6245
WD-6242
30'-42' Bins/Silos - Maximum height of
9 rings
WD-6246
48'-Maximum height of 8 rings
WD-6244
48'-Bins/Silo - 9 rings
WD-6248
Optional Auger Hood - 2 Ring
WD-6243
12'-24' Bins/Silos - with auger hood panel
WD-6247