Chapter 6: stiffeners – Grain Systems Tanks PNEG-4054A User Manual
Page 58
Close-Punch Connection for a One-Ring Top Stiffener (16 Ga) and a
Two-Ring Stiffener (16 Ga)
Reference the following information for a close-punch connection of a one-ring top stiffener (CTS-2118XX)
to a two-ring stiffener (CTS-2075XX).
Figure 6-6 One-Ring Top Stiffener (16 Ga) and a Two-Ring Stiffener (16 Ga) Close-Punch Connection
A
One-ring top stiffener (CTS-2118XX)
B
Two-ring stiffener (CTS-2075XX)
C
Splice (CTS-2091XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
Two-Ring Top Stiffener to a Two-Ring Stiffener (15–16 Ga)
Connection
Reference the following information when connecting a two-ring top stiffener (CTS-2111XX) to a two-ring
stiffener (CTS-2064XX).
Figure 6-7 Two-Ring Top Stiffener to a Two-Ring Stiffener (15–16 Ga) Connection
A
Two-ring top stiffener (CTS-2111XX)
B
Two-ring stiffener (CTS-2064XX)
C
Splice (CTS-2091XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
58
Pneg-4054A 54 Ft Diameter 40-Series Bin