Troubleshooting, Chapter 11 troubleshooting – Grain Systems Unload Augers PNEG-1430 User Manual
Page 38
38
PNEG-1430 6"-6", 6"-8", 8"-8", 8"-10" and 10"-12" 25° Bin Unloader
11. Troubleshooting
Problem
Possible Cause
Solution
Auger vibration
1. Drive belt may be overtightened, putting head
stub and flight in a bind. Damage can occur to
the auger flighting, thus causing noise. Damage
usually is caused from foreign material having
been run through the auger.
1. It may be necessary to remove the flighting
for inspection.
2. Adjust the drive belt to the proper tension.
Low capacity
1. The auger may not be getting enough grain.
1. Check that the intake has not bridged over,
restricting flow. The exposed flighting at the
auger intake should be covered with grain to
achieve maximum capacity.
2. The auger is moving too slowly.
2. Check the auger speed. Speeds slower than the
recommended speed will result in low capacity.
Auger plugs
1. The auger may be getting too much grain,
causing “jamming” inside the housing.
1. Decrease the amount of grain the auger
is gathering.
2. The motor may be too small or wired improperly.
2. If the motor is a newer lightweight aluminum
type, the next larger size should be considered.
3. The grain may be wet.
3. If wet grain or other hard-to-move material is
being augured, use a larger size motor than
recommended for normal use.
4. The auger may be jammed with foreign material.
4. Be sure there is no foreign material in the auger
such as sacks, tarp corners, etc.
5. The discharge end may be plugged.
5. Make sure the discharge end of the auger is not
plugged. A plug of the discharge end will cause
an auger plug.