Chapter 6: stiffeners – Grain Systems Tanks PNEG-4135 User Manual
Page 58
Close-Punch Connection for a Two-Ring Top Stiffener to a Two-Ring
Stiffener (16 Ga)
Reference the following information for a close-punch connection of a two-ring top stiffener (CTS-2116XX)
to a two-ring stiffener (CTS-2075XX).
Figure 6-9 Two-Ring Top Stiffener to a Two-Ring Stiffener (16 Ga) Close-Punch Connection
A
Two-ring top stiffener (CTS-2116XX)
B
Two-ring stiffener (CTS-2075XX)
C
Splice (CTS-2091XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
Two-Ring Stiffener (15-16 Ga) to a Two-Ring Stiffener (15–16 Ga)
Connection
Reference the following information when connecting a two-ring stiffener (CTS-2064XX) to a two-ring stiff-
ener (CTS-2064XX).
Figure 6-10 Two-Ring Stiffener (15-16 Ga) to a Two-Ring Stiffener (15–16 Ga) Connection
A
Two-ring stiffener (CTS-2064XX)
B
Two-ring stiffener (CTS-2064XX)
C
Splice (CTS-2091XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
58
Pneg-4135 135 Ft Diameter 40-Series Bin