beautypg.com

Installing the roof vents, Chapter 8: accessories – Grain Systems Tanks PNEG-4135 User Manual

Page 159

background image

Chapter 8: Accessories

Installing the Roof Vents

The following instructions are for installing the wire grill guard roof vent and the auto roof vent.

Before You Begin
The wire grill guard roof vent and the auto roof vent must be assembled prior to installing.

1. If the roof panel (D) does not have a pre-punched hole for the roof vent assembly (A), a hole must be

cut. The cut hole should match the roof vent assembly (A). The hole’s inside edge should be approxi-
mately 15 ft. (F) from the roof panel eave.

2. Place the three foam strips (C) on the roof panel (D), as shown, and position the roof vent assembly

(A) over the foam strips (C). Install bolts (B) and nuts (H), securing the roof vent assembly (A) to the
roof panel (D).

3. Instal bolts (G) and nuts (E) from the underside of the roof panel (D) securing the front of the hold-

down angle to the roof panel as shown. Tighten the hardware to the recommended torque specifica-
tions. See

Bolt Torque Specifications, page 26

.

Figure 8-13 Exploded view of vent housing to roof panel

A

Roof vent assembly

E

5/16 in. flange nut (S-3611)

B

5/16 x 3/4 in. flange bolt (S-7482)

F

Approximately 15 in. (0.381 m) from the roof
panel eave

C

Foam strips (side strips MIS-6781) (top
strip MIS-6780)

G

5/16 x 3/4 in. flange bolt (S-275)

D

Roof panel (part number varies)

H

5/16 in. flange nut (S-3611)

4. Apply caulk to all holes, ensuring a tight seal.

Pneg-4135 135 Ft Diameter 40-Series Bin

159