Chapter 7: Roof Assembly

Figure 7-18 Purlin location 3

A

Left-hand lower roof rafter (CTR-0239)

H

Laminated purlin (CTR-0299 and CTR-0300)

B

1/2 x 1-3/4 in. flange bolt (S-10252)

I

1/2 in. flange nut (S-10253)

C

Right-hand lower roof rafter (CTR-0239)

J

Top X-brace (CTR-0320)

D

Right purlin clip (CTR-0316)

K

Bottom X-brace (CTR-0320)

E

Left purlin clip (CTR-0315)

L

1/2 x 1-3/4 in. flange bolt (S-10252)

F

1/2 x 1-3/4 in. flange bolt (S-10252)

M

1/2 in. flange nut (S-10253)

G

1/2 in. flange nut (S-10253)

102