Series 2000 autoflow display software changes – Grain Systems PNEG-1135 User Manual
Page 43

43
2001 Top Dry Service School
Software Changes
Significant Software Changes
(Software version number is displayed on power-up)
Series 2000 Autoflow Display Software Changes
VERSION: 2.10
1)
Changed the Minimum Burner Differential to 1 Deg. Fahrenheit
2)
Fixed the problem where the burner was not shutting off when the Dry & Hold switch was
placed in the On position, the Dry Cycle was complete, and the Dryer was in the Cool Cycle. Now,
when the Dry & Hold switch is placed in the On position, and the Dry Cycle is complete, the dryer
will shut the burner off and will cool for the amount of time on the Cool Timer before stopping.
3)
Fixed a problem where the dryer was not shutting down with an Out of Grain error when the
Wet Supply Rotary Switch was exposed. Now when the Wet Supply Rotary Switch is exposed, the Fill
#1, andFill #2 delay will count down and shut off Fill System #1 & #2, then the dryer will shut down
with an Out of Grain error. If there is still grain against the Low Level Rotary Switch, the dryer can be
restarted by pressing the Stop switch to clear the error, turning the Load Auger switch to the Off
position, and pressing the Start switch. When the Start switch is pressed the screen will say Press
NOTE: If the Load Auger switch is left in the Auto position an Out of Grain error will be given on
startup.