Series 2000 Autoflow Display Software Changes
VERSION: 2.11
1)
Burner differential would not stay at 1 deg. F when the dryer
was turn off, using 2.10, now it does.
2)
When grain reaches the Storage Chamber Rotary Switch, the dryer will enter a
Cool Down Mode. The fan will run and cool the grain for 10 minutes before
shutting down due to a Storage Chamber Full error.
3)
When grain falls away from the Wet Supply Rotary Switch, the dryer will enter a
Cool Down Mode after the fill system shut off. The fan will run and cool the
grain for 10 minutes before shutting down due to a No Wet Supply error.
4)
When the Dry & Hold switch is placed in the On position the dryer will enter
a Cool Down Mode for 20 minutes before stopping. This only happens at the end
of the dry cycle.
5)
Corrected a problem with the Fans Off Delay. If there is time on this delay,
the fans and heaters will shut off during the unload cycle, after the unload cycle
is complete the delay counts down. The fans and heaters will not start again until
the delay has reached zero.
6)
Corrected a problem with the Time Until Load Off percentage set in the set-up mode.
Now, in Autobatch only, the Fill Systems will shut off if grain has not reached
the dry chamber high level rotary switch within the set percentage of the dry timer
is completed. Example: 1 hr dry time, 50% Time Until Load off. The fill systems
will shut off regardless of rotary switch status after 30min has expired.
7)
Corrected a problem with the Refill Delay. Now, in Autobatch Only. The Refill
Delay begins to count down after the unload cycle is completed. If grain has not
reached the drying chamber low level rotary switch before this delay reaches zero,