4. Assembly

20

PNEG-1722 Series II Sweep Protected Cord Slip Ring Sump

30. Feed the nine (9) stranded wires from the slip ring through one of the holes in the right junction box.

31. Connect the 1" x 48" liquid-tight flex conduit assembly to the junction box using the 1" liquid-tight

flex conduit coupling.

32. Wire the nine (9) stranded wires to the junction boxes in the following manner.

1. Thermal protection leads

a. Wire the “P1” lead from the both motors to “1”.

b. Wire the “P2” lead from the both motors to “2”.

2. Drive motor leads

a. Wire the three (3) power leads to “3”, “4” and “5”.

b. Wire the ground lead to “9”.

3. Auger motor leads

a. Wire the three (3) power leads to “6”, “7” and “8”.

b. Wire the ground lead to “9”.