10. Stiffeners

PNEG-1070 15', 18', 21', 24', 27' and 30' CHT’s

55

2.66'' Corrugation Commercial Stiffener Splice Details

When installing bottom stiffeners, in some cases the stiffener with the base plate attached will not rest on
support structure. Shim plates have been furnished and should be used to fill opening between base plate
and compression element. See

Page 65

for detail.

IMPORTANT: If shim plates are not used where required, the downward pressure of the stiffeners will not

be transferred directly to the foundation and bin failure could result.

Figure 10B

See Pages 56-59